: The smallest expected distance between two distinct nuclei. Threshold : The sensitivity level for peak detection.

| Problem | Manifestation | Workaround | |---------|---------------|-------------| | | Fewer nuclei counted on dim side | Apply Process > Subtract Background (rolling ball radius = 2x nucleus width) before ITCN | | Highly clumped nuclei (e.g., liver sections) | Undercounting by 20–40% | Use Plugins > Segmentation > Watershed before ITCN, or switch to StarDist (deep learning) | | Non-spherical nuclei (e.g., smooth muscle) | Overcounts (splits elongated nuclei) | Use manual thresholding + Analyze Particles with circularity filter (0.6–1.0) | | Very low SNR | False positives from noise | Apply Process > Filters > Median (radius 2) pre-filtering | itcn imagej plugin

– If using ITCN in published work, cite: “Image-based Tool for Counting Nuclei (ITCN)” – available via ImageJ.net, and reference the ImageJ software (Schneider et al., 2012, Nat Methods). : The smallest expected distance between two distinct nuclei

The ITCN (Interactive Thresholding and Counting of Nuclei) ImageJ plugin is a powerful tool used in the field of bioimage analysis, particularly in the quantification of nuclear staining in biological images. ImageJ, a public domain image processing program, has become a staple in the scientific community for its versatility and extensibility through plugins. The ITCN plugin, developed to address specific needs in bioimage analysis, offers advanced functionalities for thresholding, counting, and analyzing nuclei in images. The ITCN (Interactive Thresholding and Counting of Nuclei)