Canty Solidsizer Verified -

: It can correlate results within 2% of a traditional sieve , allowing companies to transition to vision-based testing without needing to overhaul their existing Quality Control (QC) documentation.

| Problem | Likely Cause | Solution | |---------|--------------|----------| | Blurry images | Flow gap too wide for small particles | Reduce gap to 1.5× largest particle | | Double images (ghosts) | Strobe pulse too long or particle velocity too high | Reduce pulse width (to 50 ns) or lower flow | | No particles visible | Window fouled | Run purge cycle or offline clean | | Counts erratic | Air bubbles in line | Install degasser or increase backpressure | | False high counts | Threshold too low (noise detected) | Increase gray threshold value | canty solidsizer

In the complex world of industrial processing, the ability to accurately measure and control particle size is not merely a matter of quality control; it is a fundamental determinant of efficiency, safety, and final product value. From pharmaceuticals to chemical manufacturing, the physical characteristics of solid particles dictate how materials flow, dissolve, and react. For decades, the industry relied on offline measurement techniques—taking a sample to a lab for analysis. However, the introduction of in-line vision technology, epitomized by the Canty SolidSizer, has revolutionized the field. By shifting the paradigm from offline estimation to real-time verification, the SolidSizer has redefined the standards of process control. : It can correlate results within 2% of